seeburger as2. The ANSI X12 EDI 810 guideline specifies segments and elements which needs to be used to properly built up an EDI 810 message. seeburger as2

 
The ANSI X12 EDI 810 guideline specifies segments and elements which needs to be used to properly built up an EDI 810 messageseeburger as2  Sender configuration incomplete - perhaps AS2ID missing

For secured communication with business partners you need to implement message level security. In the last 20 years, AS2 has become the. SEEBURGER Cloud. Scenario-Description: 2 Customers that send edi-orders in the format ANSIX12_850_V4010, called “ElectronicWorld” and “GlobalElectronics”. As new buyers examine products on the. Read more to learn all about APIs SEEBURGER BIS API SolutionNot yet a member on the new home? Join today and start participating in the discussions!SEEBURGER is also a certified Peppol Access Point Provider for AS2 and AS4. Verdict: With SEEBURGER, you will get a comprehensive solution for integrating technical partners of any size. He received our AS2 certificate and we sendURL: TLS/SSL Zertifikat: as2-ssl. Its getting failed in Seeburger Monitor. Hence if you have more than one. AS2-IDs are generally arbitrary character strings. I kknow I can use dynamic configuration for setting the subject but my mapping is 1 to N mapping and hence cant use dynamic configuration. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: support@cloud. Enter the AS2 ID, which is used here to uniquely identify the sender. g. SAP NetWeaver Technical EDI Adapter for VAN Access. or . 1. Sender configuration incomplete - perhaps AS2ID missing. SAP Business Network encloses AS2 documents within Secure/Multipurpose Internet Mail Extensions (S/MIME) envelopes and secures them by routing them over Hypertext. queryInboundRef(QueryManager. SEEBURGER provides Communication Service tools to handle the on-boarding and certificate complexity of AS2 and OFTP2 with ease. As per seeburger: – Outgoing HTTPS connections for HTTP based SEEBURGER adapters (e. 9 1 5,880. When we send message to Mail Box 2 . - Prioritizing and securing the successful completion of the projects. ResourceException: Fatal exception: javax. Cause: javax. Hi All, PI 7. R/3 is in our landscape, its component created without Party. XIRecoverableException: SEEBURGER AS2:. The flow will be: File adapter --> AS2 - > Destination party. I passed some messages via cyclone to Seeburger AS2 adapter which is being configured in SAP XI. The SEEBURGER BIS Platform One central platform, one experience, all integrations, all deployment models. resource. We work for a lot of people. I gave the following details in AS2 RCV adapter. Workshop BIS 6 Communication AS2 S-6416; Workshop BIS 6 Communication OFTP S-6417; Workshop Troubleshooting S-6435; Workshop BIS Mapper for API Use Cases S-6426;E-invoicing for utilities companies. SEEBURGER is the only platform you need for all types of integration scenarios: MFT, API/EAI, B2B/EDI, IoT/Ind. seeburger. The SEEBURGER Business Integration Suite is a full, single-source solution with modular services which you can book and combine as and how you need them. Depth knowledge and hands on with XPATH, XML, XSLT, Java, ABAP and Graphical Mapping Tool. af. The SEEBURGER BIS is a fully cloud-native, modular integration technology stack that offers flexible deployment-ready solutions for your unique ecosystem. 0084. The Seeburger PI adapter alternative with the most benefits is a migration to a cloud. As an experienced provider of integration solutions, SEEBURGER has become certified as a PEPPOL Access Point Certified Provider by OpenPEPPOL AISBL. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 MBR Gateway Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company. Reason: Fatal exception: javax. 0. SAP NetWeaver Technical EDI Adapter for EDIINT AS2. Worked on migrating EDI interfaces from Gentran system to SAP PI and Seeburger. 1. Based on the sender name and mapping used combination, the message flows further. A New Home in New Year for SAP Community: Exciting times ahead for the SAP Community!Not yet a member on the new home? Join today and start participating in the discussions!We have configured the scenario and it works as long as the partner only sends one message type (e. seeburger. please check. SEEBURGER’s API connectivity and B2B/EDI capability will help M. de DE-75015 Bretten Phone: +49 (0)7252 96 1443 Invoice Portal Service: AS2 Data Sheet Technical information to configure your AS2 connection with the SEEBURGER Cloud DATA SHEET Company Details Contact Details 1. Not yet a member on the new home? Join today and start participating in the discussions!-Migrated 50+ partners from the HP legacy AS2 Cyclone environment to the Seeburger AS2 platform. Follow RSS Feed Dear all, We have a scenario where, we are sending an IDOC from our SAP system via XI to one of our partner using AS2. connector. It also shows the type of MDN received (Async or Sync). 4. ResourceException: SEEBURGER AS2: Negative synchron MDN received. 1 ServiceProvider called “RetailHub” which sends data for both customers through one AS2-Connection 1 Supplier, called “Seeburger” that receives the orders from both partners. Forum: Compatibility. resource. Hi, I am working on a SOAP to AS2 scenario and facing the following error: Any help? Message could not be forwarded to the JCA adapter. 1 and 2. It was working fine till march 17th 2012. Verdict: With SEEBURGER, you will get a comprehensive solution for integrating technical partners of any size. 1. 3 SP9. AS2 Sender Config: Authentication key: Certificate from 1SYNC. AS2 (Applicability Statement 2) is a based. 11 and 7. Exception: AS2 message composition failed:. Configuring interfaces with the Seeburger modules for the AS2 adapters, MDN and certificates for signing, verifying and encrypting and decrypting messages. Cost efficiency results from transmitting messages cheaply and quickly via. QueryManager. September 9, 2005. Configured AS2, File, Ftp and Split 997 adapters for the EDI interfaces Extensively used SEEBURGER workbench components for Message monitoring, Message Splitting Environment: s: SAP PI 7. SEEBURGER cloud services make integrating partners’ systems and electronically exchanging data with them simple, transparent and secure. ResourceException: SEEBURGER AS2: AS2 Adapter failure # java. B2B InteroperabilityCertified Products. The SSL and AS2 certificates are different in your case. AS4's web services capability gives it the. For that I haveName: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: [email protected] am trying to compare the split Adapter of Seeburger and EDI Separator of B2B Add-on. AS2 can be used almost everywhere and provides you with a real-time status on data transmission. Integration of EDI transactions into ERP Systems like SAP R/3. 0 system. seeburger. For signature and. Executed successfully end to end installation of GRC, MDM, SLD and PI 7. Hi, I'm doing one IDOC to AS2 Scenario. resource. By 2000 Seeburger had developed software called "Jess" for writing scripts to convert data in EDIFACT or XML format for use with SAP R/3. Here I want to provide you now with a “HowTo” – Guide that has been created based on the experience of Seeburger-Consultants in various projects. , at the time of execution of the XML-to-EDI (X2E) mapping which is deployed on the XI server( which is mentioned in the Seeburger AS2 Adapter module parameters). 1. Integration of EDI transactions into ERP. We have around 25 interfaces which are currently utilizing Seeburger adapters like AS2, SFTP and Split. Our BIS Platform enables seamless connectivity of applications, people and processes, whether in the cloud, a hybrid environment or on-premises. Technical adapters. Drummond Certified products show potential partners, customers, and competitors alike that your AS2, AS4 or ebXML solutions are compliant with industry standards and interoperable with other certified software solutions. Here is my scenario which is having issue: I have configured a scenario from my system "ABC" IdocSender to "DGA" AS2 receiver {which is infact a sceanrio IDOC_AAE to AS2 Receiver adapter}. In the field B2B Directory Entry, select the entry from or to which messages should be sent. When I try to send the m. We are using Seeburger AS2 receiver adapter, running SAP PI 7. Expected Sender’s AS2 name; Expected Own AS2 name; Expected subject; The parameters from a to f are all mandatory and need to be specified while configuring the Receiver AS2 channel from B2B Toolkit 1. In the last 20 years AS2 has become the most widely used protocol for EDI in. 3 0 2,718. 1EHP1, and since this upgrade we're having problems with the Seeburger AS2 adapter (2. I've created the corresponding channels, sender and receiver agreements but I'm getting the following error: No matching inbound binding (message) found for . We have around 25 interfaces which are currently utilizing Seeburger adapters like AS2, SFTP and Split. Stefan EDI stands for Electronic Data Interchange. 115. Earlier we have shared the connectivity details with the partner like seeburger url and other details, to access the same from partner side the credentials are not mandatory. Overview. Reason: Fatal exception: com. About SEEBURGER. Involved in requirement gathering and blue print phase to migrate EDI interfaces from Seeburger to SAP PO System using B2B Add-on. In a. SFTP (as client to external server). Has anybody faced this specific scenario? This is not really a Biztalk issue but the client cert auth issue between SeeBurger & IIS. u201D. g. 4 SP 06. Configured the 997 for all inbound and outbound EDI transaction interfaces. 115. > Registering in the SEEBURGER Customer Portal via a registration link. Option 3. 3. The virus scan detected a potential threat in the transferred message. 5. It includes B2B, EDI, MFT, EAI and API integration functions that are available in any cloud, hybrid or on. seeburger. Real Experience. Click more to access the full version on SAP for Me (Login required). The Scenario In a PI/XI based EDI integration scenario, we use the Seeburger AS2 adapter to exchange EDI messages with a VAN (Value Added Network) or any system capable of sending or receiving EDI messages over internet using AS2(Applicability Statement 2) protocol. The AS2 ID is unique and hence only one party can have partner’s AS2 ID. Hi, I'm trying to send a message to a partner using AS2, I've already defined the MDN and can see the message in SXMB_MONI pending. 1 ServiceProvider called “RetailHub” which sends data for both customers through one AS2-Connection. R/3 is in our landscape, its component created without Party. Also, you'll note in the XML above that I have the alternate as2_mdn_options comment out, I've tried it both ways, and I think the response is similar or identical. In the identifier section of the partner, I added a line for Seeburger | AS2ID | theID. Industry Specific EDI Adapters by SEEBURGER : Aerospace & Defense. Whirlpool Taps SEEBURGER to Simplify Trade Customer Integration. In the last 20 years AS2 has become the most widely used protocol for EDI in many industries, such as the retail and the consumer goods industry. Skip Step 3 and 4 by clicking the Finish button. The SEEBURGER B2B/EDI solution provides a robust communication platform as it is based upon an organically grown unified code base – enabling the easy on-boarding, orchestration, and optimization of trading partners quickly, flexibly, and reliably. . We currently have B2B integration via Seeburger on dual stack PI 7. Missing inbound relation between AS2From: 'YYYY' and AS2To: 'XXX_XXX_XXX'. sap. In addition, I have implemented also B2B integration of 2 big corporations using "non-standard" Seeburger AS2 adapter. 2013. AS4 (Applicability Statement 4) is a message protocol based on web services to securely exchange B2B messages between trading partners. The B2B add-on course consists of the following modules o Module 1: Overview o Module 2: XML to EDI - Outgoing Scenarios o Module 3: EDI to XML - Incoming Scenarios o Module 4: Number Range o Module 5: Trading Partner Management o Module 6: Searching and Monitoring o Module 7: AS2 Adapter o Module 8: Archiving. 3). de DE-75015 Bretten Phone: +49 (0)7252 96 1443 MaKo Cloud Service: AS2 Data Sheet (High Security) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company Details. Follow RSS Feed Hi , I created a self-signed certificate (signing & encryption) in cyclone and uploaded it in XI. Seeburger adapters are deployed on. Issue with AS2 payload from Seeburger AS2. Part II: AS2 (MDN) >PI >R/3 (ALEAUD Idoc) After receiving the idoc xml, AS2 system will send an MDN. Hi, I'm trying to send a message to a partner using AS2, I've already defined the MDN and can see the message in SXMB_MONI pending. Implement the BIC module available in Seeburger workbench to convert the incoming EDI file to corresponding EDI-XML payload for further processing. Message Protocol: AS2. EDI is not a specific technology, but a combination of electronic processes, exchange. Hi Vinit, I guess this is IDOC->XI-AS2 scenario. I am attempting to send a flat file using Seeburger's AS2 adapter. In case of EDI, we use Seeburger adapter in XI. Now, the main issue is that we need to. , SEEBURGER AS2: AS2 Adapter failure # Outbound configuration error: Failed to get configuration from DATABASE. lang. When i tried to sign it, the channel is giving the following error. Message processing. first it tries to find an exact message subject, if it is found, message is "assigned" to this sender agreement. Hands on experience and supported seeburger AS2 and SFTP. Check if the security settings in the Sender Agreement contain the reference to the entry in KeyStore ( {TRUSTED USERS}<Views><certificate_name>). net. Can anyone please tell me how to configure the business trading partners (AS2 partner Ids) in seeburger environment. I am not sure if I am correct about seeburger AS2 adapter. Consult your web server instructions for installing the certificate and enabling HTTPS communication. History. In the field Direction, select the direction of your messages:. So its component created. The Functional Acknowledgment is mapped and converted as 997 data, which is sent back to. Handling EDI interfaces using Seeburger BIC modules. resource. SEEBURGER AG AS2 Certificate Handling How To Guide Seite 7/21 19. I have read that standard ALM alerts can be set up in PI and configured to trigger in the comm channel settings. We are trying to establis a B2B AS2 connection with a Partner (outside the network). seeburger. About SEEBURGER. Unique EDI address. Signing Key: Certificate generated in PI: i. Support for secured protocols like AS2, SFTP required for critical and sensitive financial/Customer transactions. 100% German-engineered from the ground up using a single. Also you need to import your business partner public key in visual administrator. You need to create certificates in visual administrator and exchange the public key with your business partner. SEEBURGER previously was the first EDI technology provider with an AS2 solution, which was used to turn the Hyundai Motor Company factory in Alabama into the first AS2-only automotive plant when. SAP Netweaver XI and Seeburger AS2 Adapter Sam Raju SAP Netweaver RIG Americas SAP Labs, LLC. Can anyone please tell me how to configure the business trading partners (AS2 partner Ids) in seeburger environment. 115. Connection to Seeburger Cloud can be done through a single AS2 connection. Create receiver Partner. To create a new AS2 cloudlink, follow these steps: Open the app B2B Directory. No matching routing rule was found for the transferred. Second Step: EDI Content Manager. The java port would be required 5xx00. S. Cost efficiency results from transmitting messages cheaply and quickly via the internet. 1. Seeburger has 30 years of experience with the business integration industry and has 10000 customers worldwide. Real Advantage. Communication Protocols for Hybrid Integration Like AS2, OFTP2, FTP/s, File System, SAP IDoc/RFC. Now, the client wants to MIGRATE from Seeburger to SAP provided adapters for these services. ConnectException: CConnection timed out (errno:238)The SEEBURGER Business Integration Suite provides EDI and other integrations schemes as a fully managed service in the SEEBURGER Cloud or a public cloud environment (e. Hi experts, We had a message in RWB with this error: Unable to forward message to JCA adapter. The AS2 standard explicitly says this value must be ignored but seeburger's software may be using it and essentially sending your mdn back to themselves. If u r talking about the certificate chain, then all the certificates of the chain should be loaded in J2EE. Second field in Communication channel is " Private key for Client Authentication ". Hi. General: Define a specific Channel name for AS2 Receiver Channel and choose following on the General tab. I created a new scenario. Set up and configured the AS2 communication protocol for exchanging the EDI documents for trading partners with digital Signature. The Business Integration Suite is ‘made by SEEBURGER’ and ‘made in Germany’. Appliance manufacturer taps SEEBURGER EDI technology to advance. In the Service Desk, you can open support requests for resolving existing issues or make change requests for new processes or features for your products and services. There is no certificate with such alias com. Private Key. This online Edi system offers AS2 Capability, Data Format Translation, Document Archiving, EDI Testing, Reporting/Analytics at one place. By 2000 Seeburger had developed software called "Jess" for writing scripts to convert data in EDIFACT or XML format for use with SAP R/3. 100% German-engineered from the ground up using a single source code base. And SSL are transprt layer security certificates, details of which needs to be given at the communication channel level. We are pleased that with our Business Integration Suite (BIS) we were able to complete the PEPPOL certification for AS2 and. X version of Seeburger has evolved which incorporated the adapter engine specific changes that were required with PI 7. SEEBURGER Cloud – B2B Routing Service – Datasheet AS2 (High Security) To use AS2, you need to import the certificates of the SEEBURGER Cloud. 2. Business Integration Suite is EDI software, and includes features such as archiving & retention, AS2 applications, AS2 specification compliance, certificate management,. SEEBURGER is a certified PEPPOL Access Point Provider for AS2 and AS4. resource. Back then EDI VANs had a place for connecting counter-parties’ mainframes and enabling business between them. We installed SeeBurger adapters. But when i am trying to ping the applicThis is for outbound scenario. 4. I am using Seeburger AS2 Adpater to handle EDI. Bulgaria. The EDI Sales Order message processes perfectly, resolves to the correct BIC Child Mapping, maps. com. Dear all, I would like to receive an AS2 message via the Seburger Connector from a trading partner. Signing Key: Private Key from us. AS2 (Applicability Statement 2) is a based protocol to transmit messages (especially EDI messages) safely, cheaply and quickly. . 03. Reduce time, effort and reliance on IT staff. Successful migration of seeburger third party adapters from PI landscape to use the SAP PI Connectivity add on SFTP,PGP and AS2 adapters. These parameters have already been explained in the Scenario 1 and the literal meaning remain the same. Maybe it is lower than some of the really high-end ones. It will have a description of what was the issue. SAP NetWeaver EDI Cross Industry Payment Adapter. 2. We allow alphanumeric characters and underscores. Hi All, PI 7. 1. SAP NetWeaver Technical EDI Adapter for OFTP. AS2-IDs are generally arbitrary character strings. I've trigerred already messages but they are getting this kind of error:I have read all the Seeburger guides and have trawled through the forums, but I am unable to find out if the standard Seeburger AS2 adapter or the Seeburger Workbench offers this functionality. While entering PI through the sender channel (File, AS2 or X400), following module configuration is required. If required, properties can be added or removed by clicking the Add or Remove button. ra. In the field Type, select AS2. Starting Price: Available on Request. Request async MDN (Not signed) by provided our HTTPS AS2 URL in receipt delivery address, no MDN time out. For signing - Use your private key. THE COMPANY - 1 - SEEBURGER AG 2009 THE COMPANY Founded in 1986 in Bretten, Germany 19 Global locations 7,800 customers in 50 countries rely on SEEBURGER solutions Concepts, Products and Implementation all from a single source Strong partnerships with application providers and consultants Profitable and self-financed since. 1 ServiceProvider called “RetailHub” which sends. customer. , Please do need full ASAP. The SEEBURGER BIS Platform One central platform, one experience, all integrations, all deployment models. Configured Seeburger AS2 adapter to send and receive EDI messages Configured EDI to Idoc scenarios to convert Truck EDI invoices (210) and Rail EDI invoices (410) to Invoic Idoc and configured 997 Functional acknowledgements . I am new to seeburger concepts. 2) Check if there is a firewall, and if the corresponding ports are open. In the Service Desk, you can open support requests for resolving existing issues or make change requests for new processes or features for your products and services. Prateek Raj Srivastava. Mapping Tools: IBM Sterling B2B Integrator 8. We have a lot of customers at various levels of IT maturity. 4) The corresponding communication channel is set to inactive. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 MBR Gateway Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company. conf. cer format. 1,the options are totally different than what we have in previous version of AS2 adapter. The AS2 ID is unique and hence only one party can have partner’s AS2 ID. Seeburger SFTP adapter was used to meet dis requirement. Third Step: EDI940 it is Ansi X. I created a communication channel of type AS2. Configure your EDIINT AS2 server to use the SAP Business Network URL and its protocols:Seeburger adapters are deployed on adapter engine and hence the messages traversing through them should be monitored when it enters or exits Adapter Engine. SEEBURGER is a longtime certified SAP partner with extensive SAP expertise. . Functional Acknowledgment. cloud:9843/mbr TLS/SSL certificate: as2-ms-ssl. Benefits using EDI and the VDA 4938 Message. javax. seeburger. • Analyzed and worked on ANSI x12 and EDIFACT standards. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: support@cloud. Now I have the requirement to read the "DATE" field of the MDN AS2 Header an map it to a target field. 0 are of 1. Configuring the Seeburger Message Splitter Using Seeburger Workbench. Initially we have PI7. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: support@cloud. The SEEBURGER PEPPOL Access Point accepts your data via HTTPS, AS2, AS4, SLMP (only for communication between SEEBURGER products) or SFTP and enables you to receive data in the same protocol. seeburger. The European Directive 2014/55/EU and the introduction of the European core invoice set the course for electronic invoicing in the B2G sector. communications adapters, the adapter users need access to the view. I am looking for seeburger AS2 adapter documents and configuration steps for PI7. We have some Seeburger adapters, these adapters are categorized as follows. 100% German-engineered from the ground up using a single. The user of the client software should switch to a certificate that has RSA SHA1 as the signature algorithm. 120 − 85. A New Home in New Year for SAP Community: Exciting times ahead for the SAP Community!Seeburger, AS2 and SFTP configuration and support. Attending the functional walkthroughs and make the designs converted into technical, do the link tests, Unit tests, and Assembly tests to avoid any issues after go-live or in UAT. 1. e. net. cloud. SEEBURGER has to share external IP addresses for multiple communication protocols, systems and customers if trading partners are connected directly to a single system (direct connection). 2013 Fill in the Subject Properties. We have to manipulate the file name at the receiver end using the dynamic attributes of the AS2 communication channel. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: [email protected] SFTP. My scenario is as follows: Idoc is received from ECC, passes a mapping and are sent, based on idoc receiver partner, to one of 25 recipients. 4. Therefore, you need the SPLIT997 adapter of Seeburger deployed and the adapter metadata available in your ESR. It is from R/3 --> PI --> Third Party. Please note that all the fields are case sensitive. as2. 0, Sterling Integrator 5. We are using certificates for signing and encrypting the message. Reduce time, effort and reliance on IT staff with pre‑packaged industry content, templates, mappings and connectors. In the field AS2 ID, provide the AS2 identifier for your technical connection. 0, while the adapter supports all RosettaNet Partner Interchange Pipelines (PIPs). Developed an ANSI X12 to IDoc scenario using Seeburger AS2 adapter (splitter, BIC, classifier). It is a B2B scenario and I need to send a file to a vendor. The Seeburger AS2 adapter will receive the 850 EDI file and it will be split into Order (XML file) and. B2B InteroperabilityCertified Products. cci. In the field B2B Directory Entry, select the entry from or to which messages should be sent. OFTP, FTP, X400P7 etc. ssl. 0. We asked our partner to encrypt and to sign the message. This interface is working fine, until certificate is Please check with your AS2 partner about the details of not able to process the document. There is a lot of fuss around the Split adapter of Seeburger. 1 Supplier, called “Seeburger” that receives the orders from both partners and processes. cloud. Not yet a member on the new home? Join today and start participating in the discussions!Worked on B2B integration interfaces, by using B2B integration cockpits, replaced Seeburger AS2 adapter with B2B EDI adapters. The AS2 subject has to be dynamic and depends on a particular node in the incoming message. Four of these recipients are communicating using AS2. SSLHandshakeException: sun. The ID's are case sensitive. I have already identified that SAP provides 2 different solutions for this requirement - SAP B2B Add-on & SAP Secure Add-on. The versions of Seeburger adapters that are widely used these days with XI 3. Hi all, Iam just doing File to File scenario and passing the resultant file to Partner system through AS2 adapter. AS2 is a protocol based on to quickly, cheaply, securely and reliably transmit. 3 version and SeeBurger AS2 adapter and I’m currently testing using my QA environment. Seeburger AS2 Adapter - Dynamic Attributes. 2. 31/PO, Seeburger AS2 Adapter, IDOC,SFTP with Banking system EDI process for Austrlia Retail Grocery industry Data migration(PM, PP, MM, FI, CO, SD) SAP integration solution with SCT SAP ABAP development SAP smartforms and.